| SELECTION
FLOWCHART |
|
Download
this chart and use it to aid your selection
of quarter-wave or gas-discharge devices. |
|
SERIES
3400
Standard quarter-wave |
|
SUHNER quarter-wave
lightning protectors offer the best lightning
protection available in the market, as
they form a short for surge signals. They
have
been established as a worldwide industry
standard by HUBER+SUHNER as the original
manufacturer. The products are maintenance-free
and feature the best protection performance
with both the highest surge-current-handling
capability and the lowest residual pulse
amplitude. Also, their RF performance is
superior to other designs, including passive
intermodulation.
SUHNER lightning protectors
series 3400 offer a large variety of
products and can be adapted to any application.
Besides connectorisation and mounting
principle,
the frequency range has to be selected
properly
due to their generally limited bandwidth.
Features
• Narrowband
(typically 2 to 20% of centre frequency) •
Available
within 60 MHz to 18 GHz max. (N, SMA) • Best
PIM performance • Highest current-handling
capability up to 100 kA max. • Maintenance-free
|
|
SERIES
3401
Standard gas capsule to 1.0 GHz |
|
SUHNER gas capsule
protectors make the best of the traditional
spark gap protection principle for general
applications in electronics and adapt it
perfectly to RF coaxial line applications.
At their heart are specially designed gas
capsules. The available product range of
capsules enables a selection according to
the RF transmission power with an optimum
protection performance. A very important
feature of the gas capsule protectors is
the possibility to DC/AC power outdoor equipment
via coaxial cable.
Series 3401 products can
be used broadband from DC to 1000 MHz. They
are generally designed as coaxial feedthroughs
that allow the customer to build up a protected
area according to the recommended and well-proven
protection zone principle of IEC 61312-1.
SUHNER gas capsule protectors are designed
such that the gas capsules can be easily
exchanged for new operation conditions or
replaced in the case of a necessary service.
Features
• Broadband
DC to 1 GHz •
DC transmission • Current-handling
capability 40/20 kA • Easy maintenance |
|
SERIES
3402
Standard gas capsule to 2.5 GHz |
 |
SUHNER gas capsule
protectors make the best of the traditional
spark gap protection principle for general
applications in electronics and adapt it
perfectly to RF coaxial line applications.
At their heart are specially designed gas
capsules. The available product range of
capsules enables a selection according to
the RF transmission power with an optimum
protection performance. A very important
feature of the gas capsule protectors is
the possibility of DC/AC powering outdoor
equipment via the coaxial cable.
Series 3402
products can be used broadband from DC to
2 GHz or even higher. They are generally
designed as coaxial feedthroughs that allow
the customer to build up a protected area
according to the recommended and well-proven
protection zone principle of IEC 61312-1.
SUHNER gas capsule protectors are designed
such that the gas capsules can be easily
exchanged for new operation conditions or
replaced in the case of a necessary service.
Features
• Broadband DC to 2.5 GHz •
DC
transmission •
Current-handling
capability 40/20 kA • Easy maintenance |
|
SERIES
3403
Fine Protectors |
 |
SUHNER fine
protectors are a very special group of lightning
protectors which provide a very high degree
of protection, especially for applications
with DC powering via coaxial cable. They
offer an extremely effective surge pulse
reduction, which makes them suitable to protect
even very sensitive microelectronic circuits,
e.g. GPS timing systems for CDMA mobile communications
systems.
Features
• Rugged, stable and
reliable fine protectors with very low residual
pulse energy • DC bypass function • Easy
installation – screw or bulkhead • Full
lightning protection as standard gas capsule
protectors • Gas capsule preinstalled • N
and DIN 7/16 connectors • Waterproof
IP 66 |
|
SERIES
3404
Miniature Gas Capsule Protectors |
 |
SUHNER miniature
gas capsule protectors are designed to protect
against NEMP (Nuclear Electromagnetic Pulse)
and other electromagnetic interferences.
The special design guarantees an excellent
dynamic protection performance. It includes
a fixed integrated gas capsule.
Miniature
gas capsule protectors have a bulkhead feed-through
design and can be easily installed instead
of a standard waterproof bulkhead coaxial
connector to harden existing equipment. For
lightning protection there has to be applied
different or at least additional further
protectors.
Features
• Broadband DC to
2.0 GHz •
DC transmission • Current-handling
capability 2.5 kA • Easy in-line or
panel installation |
|
SERIES
3405
Multiband Gas Capsule Protectors |
 |
SUHNER multiband
gas capsule protectors provide lightning
protection for different frequency bands
with DC on the line simultaneously. The present
product range comprises products for two
customer-specific frequency ranges each.
There can be covered frequencies in the range
of 800 MHz to the frequency limit of the
selected coaxial interface. The protection
performance is equal to standard gas capsule
protectors.
Gas capsules have to be selected
according to the RF transmission power to
achieve an optimum protection performance.
The gas capsules can be easily exchanged
for new operation conditions or replaced
in the case of a necessary service.
Features
• Availability
for applications from 800 MHz to 18 GHz (N
interface) • Narrowband (normally 2
to 20% of each centre frequency) • DC
transmission • Current-handling capability
40/20 kA • Easy maintenance |
|
SERIES
3406
Slim Line gas capsule protectors |
 |
SUHNER series
3406 Slim Line protectors provide surge protection
for any electronic equipment connected to
coaxial lines up to 5.8 GHz. The gas capsule
protection principle supports simultaneous
transmission of RF, data and DC. The gas
capsules are fixed integrated. The protectors
can handle any induced surge signals but
partial lightning current up to the specified
current handling capability only.
For higher
lightning current handling refer to our gas
capsule protector series 3401 and 3402.Multi-carrier
applications with high RF peak power and
special passive intermodulation requirements
are covered by series 3409.
Features
• Surge
protection 10 kA once, 5 kA multiple (8/20ms
test pulse according to IEC 61000-4-5) • Residual
pulse energy <450 _J (4 kV, 1.2/50ms;
2 kA, 8/20ms test pulse according toIEC61000-4-5) • Gas
capsule static sparkover voltage 150 to 250
V • Frequency range from DC to 5.8 GHz
(BNC DC to 4 GHz) • Slim inline design • Characteristic
impedance 50 Ohms • Connectorisation
N, TNC, BNC • Bulkhead mountable
|
|
SERIES
3407
Quarter wave with integrated high-pass
filter |
 |
SUHNER quarter-wave
lightning protectors with integrated high-pass
filter feature an added useful RF component
to the proven premium standard quarter-wave
protector design. Thus, they can offer an
essentially improved protection performance.
Features
• Residual
voltage reduced by 80% compared to standard
types of series 3400 • Residual energy
reduced up to factor 600 (more than 99%) • DC-blocking
at the protected side of the component |
|
SERIES
3408
Gas capsule with integrated high-pass
filter |
 |
SUHNER gas capsule
protectors with integrated high-pass filter
feature an added useful RF component to the
proven standard gas capsule protectors. Thus,
they offer a much better protection performance.
The design allows a DC injection facility
to be integrated as well. Gas capsules can
be easily exchanged for new operation conditions
or replaced in the case of a necessary service.
Features
• Residual
voltage reduced by 50% compared to standard
gas capsule protectors of series 3401/2 •
Residual
energy reduced by 75 to 85% • Decoupling
between protector and possibly deployed,
succeeding surge arresters or electronic
components with low-voltage switching barrier
as diodes or MOVs • DC-blocking on protected
side of the component • DC injection
facility products available |
|
SERIES
3409
High-power & low-IM gas capsule |
 |
SUHNER series
3409 high-power gas capsule protectors are
a new generation of ultimate gas capsule
protectors – suitable to meet the demanding
high RF performance and protection requirements
of future mobile communications transceivers
with DC powering of outdoor equipment. The
customer is freed from any RF power and IM
performance considerations. Thus the protectors
are especially suitable for multicarrier
systems.
The availability of this kind of
gas capsule protectors concerning frequency
range is not limited by the capsule (as it
is the case with standard gas capsule protectors
which are limited to applications below about
2.5 GHz). In addition, the protection performance
is superior to existing standard gas capsule
protectors.
Features • RF peak power
not limited by gas capsule • Superior
RF performance, PIM level lower – 150
dBc available • Availability for applications
from 800 MHz to 18 GHz (N interface) • Safe
extinguishing of capsule after having conducted
a surge current to ground • Up to 99%
reduced residual pulse energy • Waterproof
IP 65 min. • Gas capsule installed (73Z-0-0-548) |
|
SERIES
3410
High-power & low-IM gas capsule with
integrated high-pass filter |
|
Thus, the protectors
are especially suitable formulticarrier systems.
The integrated high-pass provides an again
improved protection performance to series
3409 protectors. But as the high-pass filter
means a DC-blocking on the protected side
of the component, this design is especially
suitable for products with integrated DC
injection facility. SUHNER series 3410 high-power
gas capsule protectors with integrated high-pass
filter belong to the new generation of ultimate
gas capsule protectors – suitable to
meet the demanding high RF performance and
protection requirements of future mobile
communications transceivers with DC powering
of outdoor equipment. The customer is freed
from any RF power and IM performance considerations.
Features • RF
peak power not limited by gas capsule • Superior
RF performance, PIM level lower –150
dBc available • Availability for applications
from 800 MHz to 2200 MHz • Safe extinguishing
of capsule after having conducted a surge
current to ground • Up to factor 500
(more than 99%) reduced residual pulse energy • Waterproof
IP 65 • Gas capsule pre-installed • DC-blocking
on protected side of component • DC
injection facility |
|
SERIES
3411
and
SERIES 3412
Data Line Protectors |
|
SUHNER series
3411 and 3412 data line protectors provide
surge protection for sensitive electronic
equipment connected to coaxial data lines.
Series 3411 protectors provide first stage
protection with high surge current handling
capability. Series 3412 protectors take care
of the fine protection with low residual
pulse energy output in combination with the
3411 products.
They are designed to meet
the requirements for high-speed data traffic
from 2Mbps up to 155Mbps according to standard
ITU-T G.703. The application recommendation
is to use them combined in series. For any
single use the operation conditions should
match with the detailed specifications of
the single protectors.
Features
Series 3411
and 3412 protectors combined: •
Current
handling capability 10kA (8/20ms test pulse
acc. to IEC 61000-4-5) • Residual pulse
energy <80mJ (4kV, 1.2/50ms; 2kA, 8/20ms
test pulse acc. to IEC 61000-4-5) • Slim
inline design • Characteristic impedance
75 Ohms • Connectorisation DIN 1.6/5.6
(others on request) • Bulkhead mountable |
|
SERIES
3413
and
SERIES 3414
Twisted Pair Data Line
Protectors |
|
The optimized
SUHNER 3413 / 3414 data line protectors can
be used in state-of-the-art Ethernet twisted
pair systems for cable classes 5e and 6,
xDSL and other high speed data transmission
applications. Series 3413 data line protectors
are first stage protectors and ought to be
used in combination with series 3414 data
line fine protectors. Normally, they are
separated by a certain cable distance. Series
3414 includes hybrid units which integrate
first stage and fine protection components.
Features • conformity
to component classes Cat 5e or 6 (ISO/IEC11801,
ANSI/TIA/EIA-586-B,
EN 10173)
• suitable for Ethernet 10 to 1000 Base-T
• interface RJ 45
• all eight lines protected
• shield and housing / grounding separated
• shielding continuity
• several grounding
and mounting options
• variants
for ”power
over ethernet” (PoE) available
Applications
Series
3413 / 3414 are designed for the protection
of current and future telecommunications
and data lines (LANs), both on the access
side and behind the main distribution
frame (MDF) on enterprise / business
and private
/ residential customer premises. All
active electronic equipment of the TP
cabling to
the PC or phone has to be protected properly.
The most important and frequently used
devices are switches, multiplexers and
cross-connects
on the access side and routers, switches,
hubs (also WLAN hubs), modems and network |
|